Żeliwogpłatvalve is a forced-sealing valve, so when the valve is closed, pressure must be applied to the disc to force the sealing surface to not leak. When the medium enters the valve from below the disc, the resistance that the operating force needs to overcome is the friction force of the valve stem and packing and the thrust generated by the pressure of the medium. The force to close the valve is greater than the force to open the valve, so ŻeliwoThe diameter of the valve stem of the gpłatvalve should be large, otherwise the valve stem will bend up failure.
2. Parameters of ŻeliwoGpłatValve
Typ zaworu
Żeliwogpłatvalve
DN
DN10~DN600
PN(MPaï¼ ‰
1.6~16Mpa
Projektowany zakres temperatur
-15â „ƒï½ž200â„ ƒ
Rodzaj połączenia:
Kołnierzowe
Typ siłownika
Napęd ręczny, siłownik pneumatyczny, hydrauliczny lub elektryczny
Odpowiednie medium
Woda, olej, gaz i różne czynniki korozyjne
Części zamienne
Materiał
Osłona korpusu
Stal kuta, stal odlewana
Trzon
Stal kuta, stal odlewana
Uszczelka
Elastyczny grafit, ulepszony elastyczny grafit, PTEE
Podkładka uszczelniająca
Ulepszony grafit Flexiblo, stal nierdzewna, PTFE
Uszczelniająca twarz
13Cr,STL, PTFE, Nylon, Z materiałem korpusu
3. Advantages of Żeliwogpłatvalve
1) The structure of the Żeliwogpłatvalve is simpler than that of the gate valve, and it is more convenient to manufacture and maintain.
2) Powierzchnia uszczelniającaof Żeliwogpłatvalve is not easy to wear and scratch, and the sealing performance is good. There is no relative sliding between the valve disc and the sealing surface of the valve body when opening and closing, so neither abrasion nor abrasion is serious. The sealing performance is good and the service life is long. .
3) When the Żeliwogpłatvalve is opened and closed, the disc stroke is small, so the height of the shut-off valve is smaller than that of the gate valve, but the structure length is longer than that of the gate valve.
4) Żeliwogpłatvalve has a large opening and closing moment, which is laborious and takes a long time.
5) The medium channel in the Żeliwogpłatvalve is tortuous, the fluid resistance is large, and the power consumption is large.
6) When the nominal pressure of the medium flow direction of the Żeliwogpłatvalve PN≤16MPa, the downstream flow is generally adopted, and the medium flows upward from the bottom of the valve flap; when the nominal pressure PN≥20MPa, the reverse flow is generally adopted, and the medium flows downward from the top of the valve flap. In order to increase the seal performance. When in use, the shut-off valve medium can only flow in one direction and cannot change the direction of flow.
7) The valve flap is often eroded when the Żeliwogpłatvalve is fully opened.
4. FAQ